Chapter 8 · Mechanical Properties of Solids
8.7 Measuring Young’s Modulus
Young’s modulus of a wire is found in the laboratory by hanging loads on it and measuring how much it stretches. The extension is less than a millimetre, so it must be read very carefully, and a warming room or a sagging support must not be mistaken for stretch. takes care of both.
8.7.1 Searle’s apparatus
Two long, identical wires hang side by side from the same rigid support (Fig. 8.21). The A carries a fixed weight that keeps it straight, and a main scale is fixed to it. The test wire B carries a hanger for slotted masses, and a vernier fixed to it slides along the main scale. A dead load on B keeps it straight before any readings are taken.
If the room warms up or the support sags, both wires move in the same way, and the vernier reading does not change. Only the stretch of the test wire under the added load moves its vernier along the scale.
Extra load
extension 0.0 mm
0 kg
1 kg
2 kg
3 kg
4 kg
Fig. 8.21 Searle’s apparatus. Each kilogram added to the test wire B moves its vernier 0.50 mm along the main scale on the reference wire A.
If an added mass M stretches the test wire, of length L and radius r, by ΔL, then from Eq. (8.7):
(8.17)
The radius is measured with a screw gauge at several places along the wire, and the length with a metre scale.
8.7.2 Using a graph
A single reading can be off. Instead, the load is increased in equal steps and the extension read at each step; the readings are repeated as the load is taken off, and the mean of each pair is used. A graph of extension against load is a straight line (Fig. 8.22), and its slope ΔL/M gives:
(8.18)
Fig. 8.22 Extension against added load for the readings of Example 8.12. The slope of the best straight line is 0.51 mm per kilogram.
Example 8.12
A steel wire 2.00 m long and 0.50 mm in diameter is tested in Searle’s apparatus. For added loads of 1, 2, 3, 4 and 5 kg, the mean extensions are 0.52, 1.02, 1.55, 2.05 and 2.56 mm. Find Young’s modulus of the steel. (Take g = 9.8 m s⁻².)
Given
Length L = 2.00 m
Radius r = 0.25 mm = 0.25 × 10⁻³ m
Readings as plotted in Fig. 8.22
Solution
Find the slope of the straight line from its first and last points:
Find πr²:
Use Eq. (8.18):
This is the usual value for steel.
Answer
2.0 × 10¹¹ N m⁻²
8.7.3 Which measurement limits the accuracy?
Write the length of the wire as L₀ to keep it apart from the extension. Combining the errors of the measured quantities as in Chapter 1, the largest possible fractional error in Y is:
(8.19)
The radius counts twice, because Y depends on r², and it is also the smallest length being measured. Suppose an extension of 1.00 mm is read to 0.01 mm with the vernier, and the diameter of 0.50 mm to 0.01 mm with a screw gauge. The 2 m length, read to a millimetre, adds almost nothing. Then:
So the radius causes four fifths of the error. That is why the diameter is measured at several places, in two directions at right angles, and the readings are averaged.
Check yourself
In Searle’s method, why does a second, reference wire hang beside the test wire?
A centimetre is smaller than a metre, so the number should get bigger, not smaller.
That’s right
Warming and a sagging support move both wires equally, so they cancel. The vernier on the test wire, read against the scale on the reference wire, shows only the stretch caused by the added load.