Chapter 10 · Thermal Properties of Matter
10.13 Thermal Resistance
Eq. (10.18) has the same form as Ohm’s law for electric current, which you will meet in Class 12: a heat current flows because of a temperature difference, just as an electric current flows because of a potential difference. The likeness makes slabs and rods easy to combine.
10.13.1 Thermal resistance
Write Eq. (10.18) as
(10.30)
where R is the of the slab or rod:
(10.31)
Its unit is K W⁻¹. A long, thin rod of a poor conductor has a large thermal resistance; a short, thick slab of copper a very small one.
10.13.2 Series and parallel
Rods joined end to end carry the same heat current, and the temperature drops across them add up, so their thermal resistances add, like resistors in series. Rods joined side by side between the same two temperatures share the heat current, so the reciprocals of their resistances add, like resistors in parallel (Fig. 10.32).
(10.32)
(10.33)
Fig. 10.32 An iron bar and a copper bar between 100 °C and 0 °C, end to end and side by side, with their thermal circuits.
Example 10.21
An iron bar and a copper bar, each 10 cm long with a cross-section of 0.010 m², are placed between reservoirs at 100 °C and 0 °C, (a) end to end and (b) side by side. Find the heat current in each case, and the temperature of the junction in (a). (K = 79 W m⁻¹ K⁻¹ for iron and 385 W m⁻¹ K⁻¹ for copper)
Given
L = 0.10 m and A = 0.010 m² for each bar
Iron: K = 79 W m⁻¹ K⁻¹; copper: K = 385 W m⁻¹ K⁻¹
Temperature difference: 100 K
Solution
Find each thermal resistance from Eq. (10.31).
End to end, the resistances add.
The junction lies below 100 °C by the drop across the iron bar.
Side by side, each bar has the full 100 K across it, and the currents add.
Answer
(a) 655 W; junction at 17 °C (b) 4640 W
10.13.3 Insulating a roof
A roof in summer is a slab between its sun-baked top surface and the room below. A layer of insulation puts a second, much larger resistance in series with it (Fig. 10.33). Nearly all the temperature drop then happens across the insulation, and the heat current falls in proportion.
Fig. 10.33 Temperature through 1 m² of a concrete roof, bare and with a 5 cm layer of foam on top.
Example 10.22
A concrete roof 12 cm thick has its top surface at 45 °C and its underside at 30 °C. (a) Find the heat flowing in through each square metre. (b) A 5.0 cm layer of foam is laid on top, with the same outer and inner temperatures. Find the new heat flow. (K = 0.8 W m⁻¹ K⁻¹ for concrete and 0.035 W m⁻¹ K⁻¹ for foam)
Given
A = 1 m²; temperature difference 15 K
Concrete: 0.12 m, K = 0.8 W m⁻¹ K⁻¹
Foam: 0.050 m, K = 0.035 W m⁻¹ K⁻¹
Solution
Resistance of the bare roof:
Heat current through it:
Resistance of the foam:
With the two in series:
Answer
(a) 100 W (b) 9.5 W, about a tenth
10.13.4 How a frozen lake thickens
In winter the ice on a lake grows from below. Heat from the water at 0 °C has to be conducted up through the ice already formed to the cold air above it. As the ice thickens, its resistance grows, so it thickens more and more slowly.
Let the ice be x thick, with the air a temperature ΔT below 0 °C. For a further layer dx to freeze, its latent heat must be conducted up through the ice in a time dt:
Rearranging and integrating from zero thickness gives the time for the ice to reach a thickness x:
(10.34)
The time grows with the square of the thickness, so ice twice as thick takes four times as long to form (Fig. 10.34).
Ice thickness
2 cm
2 cm
4 cm
6 cm
8 cm
10 cm
Fig. 10.34 Ice growing on a lake with the air at −20 °C. Choose a thickness: each further 2 cm takes longer than the last.
Example 10.23
A lake in Ladakh is covered by a thin skin of ice, with the air above it at −20 °C. How long does the ice take to grow (a) 10 cm thick, (b) 20 cm thick? (For ice: ρ = 917 kg m⁻³, K = 2.2 W m⁻¹ K⁻¹, L = 3.34 × 10⁵ J kg⁻¹)
Given
ΔT = 20 K
ρ = 917 kg m⁻³, K = 2.2 W m⁻¹ K⁻¹
L = 3.34 × 10⁵ J kg⁻¹
Solution
Use Eq. (10.34) with x = 0.10 m.
Doubling x multiplies the time by four.
Answer
(a) about 9.7 h (b) about 39 h
Check yourself
A copper rod and a steel rod of the same length and thickness are joined end to end between 100 °C and 0 °C. Where is the larger temperature drop?
A centimetre is smaller than a metre, so the number should get bigger, not smaller.
That’s right
The same heat current flows through both rods, and the drop across each is {V:H} × {A:R}. Steel has the larger resistance, so it takes the larger share of the 100 K.