Chapter 3 · Current Electricity
3.15 Ammeters and Voltmeters
The heart of a moving-coil meter is a galvanometer: a light coil that turns in a magnetic field when a current passes through it, moving a needle across a scale. A typical galvanometer swings to the end of its scale for a current of a few milliamperes or less, its full-scale current, and its coil has a resistance G of tens of ohms.
On its own it can carry only that tiny current. Adding one resistor turns it into an ammeter or a voltmeter (Fig. 3.31).
Fig. 3.31 (a) An ammeter: a galvanometer with a small shunt S across it. (b) A voltmeter: a galvanometer with a large resistance R in series.
3.15.1 The Ammeter
An is joined in series with the circuit, so all the current passes through it. To measure a current I much larger than the full-scale current, a small resistance S, the , is joined in parallel with the galvanometer. The galvanometer takes just its full-scale current and the shunt carries all the rest. Both have the same voltage across them, which gives
(3.70)
The ammeter’s resistance is that of G and S in parallel, which is less than S. An ideal ammeter has zero resistance, so that putting it into a circuit does not change the current it measures.
3.15.2 The Voltmeter
A is joined in parallel with the part of the circuit whose voltage it measures. To read up to a voltage V, a large resistance R is put in series with the galvanometer, so that V drives exactly the full-scale current through both. So
(3.71)
An ideal voltmeter has an infinite resistance, so that it draws no current from the circuit it measures.
3.15.3 How Meters Disturb a Circuit
Real meters fall short of the ideal, and the way they are connected decides the error. Suppose a resistance R is measured as the voltmeter reading divided by the ammeter reading, using real meters that each have some resistance of their own. There are two ways to connect them (Fig. 3.32).
Fig. 3.32 Two ways to measure a 100 Ω resistor with an ammeter of 1.0 Ω and a voltmeter of 1000 Ω, from a 10 V supply. Neither gives exactly 100 Ω.
With the voltmeter directly across R, it reads the right voltage, but the ammeter also counts the current through the voltmeter. The result is R and the voltmeter in parallel, a little too small:
(3.72)
With the voltmeter across both the ammeter and R, the ammeter reads the right current, but the voltmeter also counts the drop across the ammeter. The result is a little too large:
(3.73)
For a small R, compared with the voltmeter’s resistance, the first way is better; for a large R, compared with the ammeter’s resistance, the second.
Example 3.26
Two 10 kΩ resistors are joined in series across a 12 V supply, so that each should have 6.0 V across it. What does a voltmeter read across one of them if its resistance is (a) 10 kΩ (b) 1.0 MΩ?
Given
Two resistors of 10 kΩ in series Supply 12 V Voltmeter resistance 10 kΩ or 1000 kΩ
Solution
For part (a), the voltmeter and the resistor it sits across form a parallel pair. That pair and the other resistor make a potential divider.
For part (b), repeat with 1000 kΩ.
A voltmeter is trustworthy only if its resistance is far larger than the resistance it is placed across.
Answer
(a) 4.0 V (b) 5.97 V, against the true 6.0 V
Example 3.27
A galvanometer has a coil of resistance 50 Ω and gives full-scale deflection for 2.0 mA. How would you turn it into (a) an ammeter reading up to 1.0 A (b) a voltmeter reading up to 10 V?
Given
G = 50 Ω Full-scale current 2.0 mA = 2.0 × 10⁻³ A Ranges 1.0 A and 10 V
Solution
For part (a), find the shunt from Eq. (3.70).
For part (b), find the series resistance from Eq. (3.71).
Answer
(a) a 0.10 Ω shunt in parallel (b) 4950 Ω in series
Check yourself
How is a galvanometer turned into a voltmeter?
A centimetre is smaller than a metre, so the number should get bigger, not smaller.
That’s right
A large series resistance makes the full voltage drive only the full-scale current through the coil, and gives the meter the large resistance a voltmeter needs.