Chapter 3 · Current Electricity

3.4 Ohm’s Law

In 1827 Georg Simon Ohm found that the current through a metal wire at a fixed temperature is proportional to the potential difference across it. If V is the potential difference and I the current,

(3.3)

The constant R is the of the wire, and this rule is . The SI unit of resistance is the , written Ω:

3.4.1 Resistance and Resistivity

What does the resistance depend on? Take a slab of a material, of length l and cross-sectional area A, with resistance R. Place two identical slabs end to end (Fig. 3.5). The same current I passes through both, and each needs a potential difference V, so the pair needs 2V:

(3.4)

Doubling the length doubles the resistance. In general the resistance is proportional to the length:

(3.5)

Fig. 3.5 Two slabs end to end need twice the voltage for the same current. Cutting a slab in half along its length leaves half the current at the same voltage.

Now cut the slab in half along its length. Each half has area A/⁠2. With the same V across it, each half carries only half the current, so its resistance is twice as large:

(3.6)

So the resistance is inversely proportional to the area,

(3.7)

and putting Eqs. (3.5) and (3.7) together,

(3.8)

The constant ρ is the of the material. It depends on the material and its temperature, but not on the size or shape of the piece. Its unit is the Ω m. Copper at room temperature has ρ ≈ 1.7 × 10⁻⁸ Ω m.

For a conductor that obeys Ohm’s law, a graph of V against I is a straight line through the origin. Raise the voltage across a 10 Ω resistor step by step (Fig. 3.6): the current rises in the same proportion, and the slope of the line is the resistance.

Battery voltage

2.0 V

2 V

4 V

6 V

8 V

10 V

Fig. 3.6 A 10 Ω resistor across a battery of 2 V to 10 V. Every reading of V against I lies on one straight line, of slope 10 Ω.

3.4.2 Current Density

The  j is the current per unit area through a surface at right angles to the flow:

(3.9)

Its unit is the A m⁻². In a wire of length l the field is uniform, so V = El. Putting V = El, I = jA and R = ρl/⁠A into Ohm’s law gives

(3.10)

In vector form, with the σ = 1/⁠ρ,

(3.11)

This form of Ohm’s law belongs to a point inside the material, not to a whole wire. A field of a given strength drives the same current density in any piece of the same material, whatever its shape.

Example 3.2

A copper wire in a house circuit is 20 m long and has a cross-section of 1.5 mm². It carries a current of 10 A. The resistivity of copper is 1.7 × 10⁻⁸ Ω m. Find (a) the resistance of the wire (b) the potential difference across it (c) the current density in it (d) the electric field inside it.

Given

Length l = 20 m Area A = 1.5 mm² = 1.5 × 10⁻⁶ m² Current I = 10 A Resistivity ρ = 1.7 × 10⁻⁸ Ω m

Solution

For part (a), use the resistivity, length and area.

For part (b), apply Ohm’s law to the whole wire.

For part (c), divide the current by the area.

For part (d), use the point form of Ohm’s law.

As a check, the field times the length gives back the voltage: 0.11 V m⁻¹ × 20 m ≈ 2.3 V.

Answer

(a) R = 0.23 Ω (b) V = 2.3 V (c) j = 6.7 × 10⁶ A m⁻² (d) E = 0.11 V m⁻¹

Example 3.3

A metal wire has a resistance of 5.0 Ω. It is drawn out until its length is doubled. Its volume does not change. Find its new resistance.

Given

Old resistance R = 5.0 Ω New length l′ = 2l Volume unchanged, so A′l′ = Al

Solution

Doubling the length at a fixed volume halves the cross-section.

Put the new length and area into R = ρl/⁠A. The resistivity is unchanged, since the material is the same.

Answer

R′ = 20 Ω, four times as large

Check yourself

A wire has resistance R. A second wire of the same metal is twice as long and has twice the diameter. What is its resistance?

Chapter 3 · Current Electricity

3.4 Ohm’s Law

In 1827 Georg Simon Ohm found that the current through a metal wire at a fixed temperature is proportional to the potential difference across it. If V is the potential difference and I the current,

(3.3)

The constant R is the of the wire, and this rule is . The SI unit of resistance is the , written Ω:

3.4.1 Resistance and Resistivity

What does the resistance depend on? Take a slab of a material, of length l and cross-sectional area A, with resistance R. Place two identical slabs end to end (Fig. 3.5). The same current I passes through both, and each needs a potential difference V, so the pair needs 2V:

(3.4)

Doubling the length doubles the resistance. In general the resistance is proportional to the length:

(3.5)

Fig. 3.5 Two slabs end to end need twice the voltage for the same current. Cutting a slab in half along its length leaves half the current at the same voltage.

Now cut the slab in half along its length. Each half has area A/⁠2. With the same V across it, each half carries only half the current, so its resistance is twice as large:

(3.6)

So the resistance is inversely proportional to the area,

(3.7)

and putting Eqs. (3.5) and (3.7) together,

(3.8)

The constant ρ is the of the material. It depends on the material and its temperature, but not on the size or shape of the piece. Its unit is the Ω m. Copper at room temperature has ρ ≈ 1.7 × 10⁻⁸ Ω m.

For a conductor that obeys Ohm’s law, a graph of V against I is a straight line through the origin. Raise the voltage across a 10 Ω resistor step by step (Fig. 3.6): the current rises in the same proportion, and the slope of the line is the resistance.

Battery voltage

2.0 V

2 V

4 V

6 V

8 V

10 V

Fig. 3.6 A 10 Ω resistor across a battery of 2 V to 10 V. Every reading of V against I lies on one straight line, of slope 10 Ω.

3.4.2 Current Density

The  j is the current per unit area through a surface at right angles to the flow:

(3.9)

Its unit is the A m⁻². In a wire of length l the field is uniform, so V = El. Putting V = El, I = jA and R = ρl/⁠A into Ohm’s law gives

(3.10)

In vector form, with the σ = 1/⁠ρ,

(3.11)

This form of Ohm’s law belongs to a point inside the material, not to a whole wire. A field of a given strength drives the same current density in any piece of the same material, whatever its shape.

Example 3.2

A copper wire in a house circuit is 20 m long and has a cross-section of 1.5 mm². It carries a current of 10 A. The resistivity of copper is 1.7 × 10⁻⁸ Ω m. Find (a) the resistance of the wire (b) the potential difference across it (c) the current density in it (d) the electric field inside it.

Given

Length l = 20 m Area A = 1.5 mm² = 1.5 × 10⁻⁶ m² Current I = 10 A Resistivity ρ = 1.7 × 10⁻⁸ Ω m

Solution

For part (a), use the resistivity, length and area.

For part (b), apply Ohm’s law to the whole wire.

For part (c), divide the current by the area.

For part (d), use the point form of Ohm’s law.

As a check, the field times the length gives back the voltage: 0.11 V m⁻¹ × 20 m ≈ 2.3 V.

Answer

(a) R = 0.23 Ω (b) V = 2.3 V (c) j = 6.7 × 10⁶ A m⁻² (d) E = 0.11 V m⁻¹

Example 3.3

A metal wire has a resistance of 5.0 Ω. It is drawn out until its length is doubled. Its volume does not change. Find its new resistance.

Given

Old resistance R = 5.0 Ω New length l′ = 2l Volume unchanged, so A′l′ = Al

Solution

Doubling the length at a fixed volume halves the cross-section.

Put the new length and area into R = ρl/⁠A. The resistivity is unchanged, since the material is the same.

Answer

R′ = 20 Ω, four times as large

Check yourself

A wire has resistance R. A second wire of the same metal is twice as long and has twice the diameter. What is its resistance?