Chapter 6 · Electromagnetic Induction
6.8 AC Generator
Electromagnetic induction has been put to work in many ways. The most important is the generation of alternating current. The generators in power stations are highly developed machines delivering hundreds of megawatts, but the principle behind them is simple. Nikola Tesla’s work in the 1880s did much to make such machines the basis of today’s power systems.
As Section 6.4 showed, one way to change the flux through a loop is to turn it. As a coil turns in a field B, the area it presents to the field is A cos θ, where θ is the angle between B and the area vector. An works this way. It turns mechanical energy into electrical energy.
Fig. 6.19 shows its parts. A coil, the , is mounted on a shaft whose axis is at right angles to the field. Something outside turns it: falling water, steam, wind or your own legs. As it turns, the flux through it changes and an emf is induced. The ends of the coil are joined to , so the turning coil stays connected to the outside circuit.
Fig. 6.19 A simple ac generator. The armature coil turns on an axle between the poles of a magnet; slip rings and brushes connect it to the load.
Let the coil turn at a steady angular speed ω, and start the clock when the field is along the area vector. At time t the angle between them is
and the flux through each turn is
For a coil of N turns, Faraday’s law gives
so the instantaneous emf is
(6.22)
Its largest value, NBAω, comes when sin ωt = ±1. Calling it ε₀,
(6.23)
As sin ωt swings between +1 and −1, the emf swings between +ε₀ and −ε₀, changing its polarity twice in every turn (Fig. 6.20). It is largest at θ = 90° and 270°, when the plane of the coil lies along the field and the flux through it is zero, because that is where the flux changes fastest. It is zero when the coil faces the field squarely, with the flux at its largest and, for an instant, not changing.
Fig. 6.20 A coil turning between the poles of a magnet, seen end-on, with its area vector A. The emf follows sin ωt and is largest when the flux, dashed, is zero and changing fastest.
The current such an emf drives changes direction again and again, so it is called . Since ω = 2πν, where ν is the number of turns per second,
(6.24)
Eqs. (6.22) to (6.24) give the emf at each instant. The next chapter shows how to find its average values.
In power stations the mechanical energy comes from water falling through a dam (hydroelectric generators), or from steam at high pressure, raised by burning coal or gas (thermal generators) or by the heat of nuclear fuel (nuclear generators). Large modern generators deliver 500 MW or more, enough to light five million 100 W bulbs. In most of them the coils are held still and electromagnets turn inside them. In India the supply alternates at 50 Hz; in some countries, such as the USA, at 60 Hz.
Example 6.16
Arjun pedals an exercise bicycle whose pedals turn a coil of 150 turns and area 0.080 m² at one revolution per second, in a uniform field of 0.020 T at right angles to the axis of rotation. Find the peak emf of the coil.
Given
Turns N = 150, area A = 0.080 m² Field B = 0.020 T Rate ν = 1.0 s⁻¹
Solution
The peak emf is NBAω, from Eq. (6.23), with ω = 2πν.
Answer
ε₀ = 1.5 V
Example 6.17
A generator coil of 100 turns, each of area 0.050 m², turns at 50 revolutions per second in a uniform field of 0.10 T. Find (a) its peak emf, and (b) the emf when the coil has turned through 30° from the position of largest flux, and the time this takes.
Given
Turns N = 100, area A = 0.050 m² Field B = 0.10 T Rate ν = 50 s⁻¹
Solution
(a) From Eq. (6.23):
(b) The coil turns through 360° in 1/50 s, so it reaches 30° after
Starting the clock at the position of largest flux, the emf is ε₀ sin ωt:
Answer
(a) 157 V; (b) 79 V, 1/600 s after the largest flux
Did you know?
Why 3000 revolutions a minute
A simple generator with one pair of poles makes one cycle of emf in each revolution. To supply India’s 50 Hz, the steam-turbine generators of thermal power stations spin at 50 revolutions a second, 3000 a minute. Hydroelectric generators turn far more slowly, so they carry many pairs of poles round a wide rotor, each pair adding one cycle per turn.
Watch out
Largest emf, zero flux
It is tempting to think the emf is largest when the most field passes through the coil. It is the other way round: the emf is largest when the flux is zero, because that is where the flux changes fastest.
Check yourself
A coil turns steadily in a uniform magnetic field. At which position is the emf induced in it largest?
A centimetre is smaller than a metre, so the number should get bigger, not smaller.
That’s right
The emf follows the rate of change of flux. With the plane of the coil along the field the flux is zero but changing fastest, so the emf is largest: N B A omega.