Chapter 6 · Electromagnetic Induction

6.3 Magnetic Flux

Faraday’s great insight was a single quantity that measures how much magnetic field passes through a coil. It is the , defined in the same way as the electric flux of Chapter 1. Its symbol is Φ; the equations add a small B below it, to tell it apart from electric flux.

6.3.1 A flat surface in a uniform field

Take a flat surface of area A in a uniform magnetic field B. Describe the surface by its  A, a vector at right angles to the surface whose size is the area. If the angle between B and A is θ, the magnetic flux through the surface is

(6.1)

The flux is largest, BA, when the field crosses the surface at right angles (θ = 0). It falls as the surface tilts, and it is zero when the field runs along the surface (θ = 90°), because then no field passes through it. Turn the surface right over (θ = 180°) and the flux is −BA: the same field now passes through it the other way.

Angle between B and A

Flux 20.0 mWb

0°

30°

60°

90°

180°

Fig. 6.5 Turn the loop. Its area is 0.050 m² and the field is 0.40 T. Only the field lines that pass through the loop, drawn dark, count, and their number follows cos θ.

A useful picture is to count field lines. Draw the field with a fixed number of lines per square metre; then the flux through a surface is the number of lines that cross it. Tilting a loop lets more of the lines slip past it.

6.3.2 Any field, any surface

When the field changes from place to place, or the surface is curved, split the surface into small elements (Fig. 6.6). Each element dA is nearly flat, and the field B over it is nearly uniform, so its flux is B · dA. The flux through the whole surface is the sum

(6.2)

Fig. 6.6 A curved surface split into small elements. Each has its own area vector dA and its own field B; the flux is the sum of B · dA over all of them.

where “all” means every element of the surface. Magnetic flux is a scalar. Its SI unit is the (Wb), named after the German physicist Wilhelm Weber:

A loop has two faces, so its area vector could point either way. The choice fixes the sign of the flux, and either choice works, as long as you keep to it. What matters, as the next section shows, is how the flux changes.

Example 6.1

A square loop of side 20 cm is placed in a uniform magnetic field of 0.50 T, with the normal to the loop at 60° to the field. Find the flux through the loop. What is the flux when the loop is turned so that its plane lies along the field?

Given

Side a = 0.20 m Field B = 0.50 T Angle between B and A: θ = 60°

Solution

First, the area of the loop.

Then the flux, from Eq. (6.1).

With its plane along the field, the area vector is at right angles to the field. Then θ = 90°, cos 90° = 0, and no field passes through the loop.

Answer

Φ = 0.010 Wb; zero with the plane along the field

Example 6.2

A flat rectangular loop 30 cm by 20 cm lies in the plane of the page. Over its left half there is a uniform field of 0.50 T out of the page, and over its right half a uniform field of 0.20 T into the page. Taking the area vector out of the page, find the flux through the loop.

Given

Each half: 15 cm by 20 cm Left half: B = 0.50 T, along the area vector, θ = 0 Right half: B = 0.20 T, against the area vector, θ = 180°

Solution

Both halves have the same area.

The field is uniform over each half, so the sum in Eq. (6.2) has just two terms. The left half gives

and the right half, where the field points against the area vector, gives

Add the two.

Answer

Φ = 9.0 × 10⁻³ Wb

Key idea

Three ways to change a flux

The flux through a loop depends on three things: the field B, the area A and the angle θ between the field and the area vector. Change any one of them and the flux changes. The rest of this chapter is about what such changes do.

Check yourself

A square loop sits at right angles to a uniform magnetic field. The field is doubled and the side of the square is halved. What happens to the flux through the loop?

Chapter 6 · Electromagnetic Induction

6.3 Magnetic Flux

Faraday’s great insight was a single quantity that measures how much magnetic field passes through a coil. It is the , defined in the same way as the electric flux of Chapter 1. Its symbol is Φ; the equations add a small B below it, to tell it apart from electric flux.

6.3.1 A flat surface in a uniform field

Take a flat surface of area A in a uniform magnetic field B. Describe the surface by its  A, a vector at right angles to the surface whose size is the area. If the angle between B and A is θ, the magnetic flux through the surface is

(6.1)

The flux is largest, BA, when the field crosses the surface at right angles (θ = 0). It falls as the surface tilts, and it is zero when the field runs along the surface (θ = 90°), because then no field passes through it. Turn the surface right over (θ = 180°) and the flux is −BA: the same field now passes through it the other way.

Angle between B and A

Flux 20.0 mWb

0°

30°

60°

90°

180°

Fig. 6.5 Turn the loop. Its area is 0.050 m² and the field is 0.40 T. Only the field lines that pass through the loop, drawn dark, count, and their number follows cos θ.

A useful picture is to count field lines. Draw the field with a fixed number of lines per square metre; then the flux through a surface is the number of lines that cross it. Tilting a loop lets more of the lines slip past it.

6.3.2 Any field, any surface

When the field changes from place to place, or the surface is curved, split the surface into small elements (Fig. 6.6). Each element dA is nearly flat, and the field B over it is nearly uniform, so its flux is B · dA. The flux through the whole surface is the sum

(6.2)

Fig. 6.6 A curved surface split into small elements. Each has its own area vector dA and its own field B; the flux is the sum of B · dA over all of them.

where “all” means every element of the surface. Magnetic flux is a scalar. Its SI unit is the (Wb), named after the German physicist Wilhelm Weber:

A loop has two faces, so its area vector could point either way. The choice fixes the sign of the flux, and either choice works, as long as you keep to it. What matters, as the next section shows, is how the flux changes.

Example 6.1

A square loop of side 20 cm is placed in a uniform magnetic field of 0.50 T, with the normal to the loop at 60° to the field. Find the flux through the loop. What is the flux when the loop is turned so that its plane lies along the field?

Given

Side a = 0.20 m Field B = 0.50 T Angle between B and A: θ = 60°

Solution

First, the area of the loop.

Then the flux, from Eq. (6.1).

With its plane along the field, the area vector is at right angles to the field. Then θ = 90°, cos 90° = 0, and no field passes through the loop.

Answer

Φ = 0.010 Wb; zero with the plane along the field

Example 6.2

A flat rectangular loop 30 cm by 20 cm lies in the plane of the page. Over its left half there is a uniform field of 0.50 T out of the page, and over its right half a uniform field of 0.20 T into the page. Taking the area vector out of the page, find the flux through the loop.

Given

Each half: 15 cm by 20 cm Left half: B = 0.50 T, along the area vector, θ = 0 Right half: B = 0.20 T, against the area vector, θ = 180°

Solution

Both halves have the same area.

The field is uniform over each half, so the sum in Eq. (6.2) has just two terms. The left half gives

and the right half, where the field points against the area vector, gives

Add the two.

Answer

Φ = 9.0 × 10⁻³ Wb

Key idea

Three ways to change a flux

The flux through a loop depends on three things: the field B, the area A and the angle θ between the field and the area vector. Change any one of them and the flux changes. The rest of this chapter is about what such changes do.

Check yourself

A square loop sits at right angles to a uniform magnetic field. The field is doubled and the side of the square is halved. What happens to the flux through the loop?