Chapter 2 · Electrostatic Potential and Capacitance
2.20 Charge Sharing and Capacitor Networks
Join two charged capacitors, positive plate to positive plate and negative plate to negative plate (Fig. 2.42). Charge flows until both have the same potential difference, the . The joined positive plates form an isolated group, so their total charge cannot change:
(2.81)
Fig. 2.42 A 3.0 μF capacitor at 100 V is joined to a 6.0 μF capacitor at 40 V. Charge flows until both are at 60 V, and the stored energy falls from 19.8 mJ to 16.2 mJ.
The stored energy always falls. Working out ½C₁V₁² + ½C₂V₂² − ½(C₁ + C₂)V² gives the energy lost:
(2.82)
This is never negative, and it is zero only if the two capacitors were already at the same potential difference. The lost energy becomes heat in the connecting wires, with a little radiation. Strangely, the amount does not depend on the resistance of the wires: with thin wires the current is smaller but flows for longer, and the heat comes out the same.
If the capacitors are joined the other way round, positive plate to negative, their charges partly cancel. Then V = (C₁V₁ − C₂V₂)/(C₁ + C₂), and the loss is given by Eq. (2.82) with V₁ + V₂ in place of V₁ − V₂.
Example 2.24
A 3.0 μF capacitor charged to 100 V and a 6.0 μF capacitor charged to 40 V are disconnected from their supplies. Find the common potential and the energy lost when they are joined (a) positive plate to positive plate (b) positive plate to negative plate.
Given
C₁ = 3.0 μF at V₁ = 100 V C₂ = 6.0 μF at V₂ = 40 V
Solution
For part (a), the charges on the joined positive plates add.
The energy lost follows from Eq. (2.82).
For part (b), the joined plates carry charges of opposite sign, which partly cancel.
The loss now uses the sum of the two potential differences.
Answer
(a) 60 V, 3.6 mJ lost (b) 6.7 V, 20 mJ lost
2.20.1 Networks That Are Neither Series nor Parallel
Some networks cannot be broken into series and parallel parts (Fig. 2.43). A general method always works. Give each junction an unknown potential, taking one end of the network as zero and the other as V. Then use two facts: the charge on each capacitor is its capacitance times the potential difference across it, and any group of plates joined only to one another, cut off from the battery, keeps a total charge of zero.
Fig. 2.43 A bridge network. C₅ joins two points, X and Y, and is neither in series nor in parallel with any other capacitor, so the network needs the general method.
Example 2.25
In the bridge network of Fig. 2.43, C₁ = 1.0 μF joins A to X, C₂ = 2.0 μF joins X to B, C₃ = 2.0 μF joins A to Y, C₄ = 1.0 μF joins Y to B, and C₅ = 3.0 μF joins X to Y. A 90 V supply is connected across A and B. Find the potentials of X and Y, the charge on each capacitor, and the effective capacitance of the network.
Given
B at 0 V, A at 90 V Capacitances in microfarads: C₁ = 1.0, C₂ = 2.0, C₃ = 2.0, C₄ = 1.0, C₅ = 3.0
Solution
Call the unknown potentials of X and Y, in volts, x and y. The plates joined at X form an isolated group, so their charges add to zero. Working in microcoulombs,
The same holds at Y.
Solving the two equations together gives
The charge on each capacitor is its capacitance times the potential difference across it.
The supply delivers the charge on C₁ and C₃ together.
Answer
X at 40 V, Y at 50 V; charges 50, 80, 80, 50 and 30 μC; 1.4 μF
When the ratios match, C₁/C₂ = C₃/C₄, the points X and Y come to the same potential and C₅ carries no charge at all. The bridge is then said to be balanced, and C₅ can be left out. You will meet the same idea with resistors in Chapter 3, as the Wheatstone bridge.
Check yourself
A charged capacitor is joined to an identical uncharged one. What fraction of the stored energy is lost?
A centimetre is smaller than a metre, so the number should get bigger, not smaller.
That’s right
The charge is shared equally, so V halves while C doubles. The energy becomes ½(2C)(V/2)² = ¼CV², half the starting energy; the other half heats the wires.